Re-Piping Services Plumbing Service on November 27, 2024 in Jacksonville Beach, (32250)

Plumber Notes: A pool crew ripped out a 4-in main in the backyard, so now we have to reroute it. It’s about a 45-ft trench going around the new pool. Must return in the morning to finish. On day two, we were able to finish digging the trench and installing what ended up to be about 50 ft of pipe. We checked for slope to make sure it had fall and and backfield for support underneath the pipes. The homeowner was not home to allow us to test the system from the inside. The job is complete…. read more


Water Leaks Plumbing Service on November 27, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Customer had water leaking from light fixture in the closet. Went in the attic to track down the pipe. Removed insulation, 3/4 tee, look like wasn’t glued with the correct glue dripping. Cut out and replaced 3/4 cpvc tee…. read more


Water Leaks Plumbing Service on October 28, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Arrived at customer’s house. Customer stated that he was seeing water come from the floor. Upon further look into the problem we did notice the water on the floor. So we cut into the drywall behind the shower in the bedroom closet. We located the leak. The leak was coming from The shower rod because there was only pipe dope no Teflon tape used for shower rod. So we took out the shower rod out and put Teflon tape and pipe dope on the rod and screwed it back in. Ran the shower to insure there was no more leaks. Leak has stopped. Also checked tub area for leaks. There was none. We put access panels up to cover the holes We used a 14×14 for the bottom for the tub and a 8×8 for the tub and shower valve area. We checked the tub for leaks there was none. Cleaned up area job is complete…. read more


Re-Piping Services Plumbing Service on July 15, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Arrived shut off main water meter. Cut out the damaged pipe located in the wall of the garage. Replaced it with 2 couplings and some new pipe. Dug up the shut off valve located on the outside of the house cut out old damaged valve. Replaced with a new 3/4 CPVC ball valve. And tied in with a PVC to CPVC transition coupling, a 1″ PVC 90 some 1″ pipe and a 1 ” coupling. Waited for glue time. Turned on water and tested for leaks. No leaks present and valve is functioning properly. Backfilled the dirt…. read more


Water Heater Plumbing Service on July 1, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Turned off gas to heaters and shut power off and shut the water down. Then we cut the old tankless heaters loose and installed new ones (A.O smiths tankless heater for a rinnai.) We then tested the water lines and gas lines to ensure no leaks and proper connections. We then plugged in the new heaters and set the temp to 140. Which is typical for restaurants. Tested for hot water…. read more


Re-Piping Services Plumbing Service on June 4, 2024 in Jacksonville Beach, (32250)

Plumber Notes: We will start by shutting the water off at the back flow and cut out and replace 4″ sch.80 cpvc butterfly main shut off valve and continue cutting out and replacing all other valves in the garage. Once we have completed replacing the valves we will turn the water back on and test for leaks once the leak test is complete we will then go floor to floor and balance the pressure of the building. We will need access to at least one condominium on each floor during the balancing process Also during balancing process we will flush and clean regulators as needed. We will re insulate piping in garage where we have to remove existing insulation to replace the valves. Betros is not responsible for any drywall tile concrete flooring trim etc damage or repair. If you would like us to proceed with the work please see the accept/e-sign here link at the bottom of the estimateUpdated: Need to replace circuit setter for fifth floor. We will turn the water off and remove old valve and install new one and test for leaks once tested for leaks we will begin the final balance of the building once the building is balanced we will start clean up and pull off the job once the building has equal flow and pressure to all floors…. read more


Sewer and Drain Plumbing Service on May 28, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Was able to relocate well pump successfully with no leaks. … read more


Re-Piping Services Plumbing Service on April 12, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Dug up 85 ft from the meter to the house to lay one inch PVC for the new main line when we start to repipe backfield halfway so that the internet guy can put a new cable and our trench for their internet because it got cut in half. When we return I will finish backfilling and resetting after I hook it to the meter and to the house but water service has been run for new connection. Completed everything on the punch list, backfilled dirt and tested for leaks. Checked everything and it is up to code. Job is complete…. read more


Betros Plumbing Services Plumbing Service on February 22, 2024 in Jacksonville Beach, (32250)

Plumber Notes: Customer requests a re-pipe for water mainline inch and a half that ties into the booster pump, and the facility. We will remove all existing ball valve, check valves, all existing cpvc inch and a half pipe, pressure reducer valve, all existing inch and a half copper pipe, and Y water strainer. For re-pipe we will use cpvc only inch and a half pipe and fittings. We will install new brass ball valves and tie in the new cpvc water line to the existing line by using a FIP 1 1/2 pro press and a MIP cpvc fitting. We will install new ball valves, check valves, PRV, water Y strainer, and gauges. For the Water Softener, we will remove the existing CPVC inch and a half Valve, T’s fittings, CPVC, three inch and a half ball valves, and bypass system for Water Softener. For the control board to the booster pump, we will turn the power off at the breaker, disconnect all the hardwire, and remove the existing control board. We will install the new Lenze i1550 1hp single phase 208v and reconnect the hardwire to the new control board. We will secure the new control board to the plywood backboard. For the restroom, we will change out closet diaphragm, we changed out one urinal diaphragm. For the first in the women’s bathroom, we change out the spud, and we replaced the Sensor Sloan valve. For all the repair during the timeframe, we turn off the water at the backflow. When the job was completed, we turned the water back on to check for leaks, no leaks. And we make sure that the control board and the booster pump function properly…. read more


Betros Plumbing Services Plumbing Service on February 2, 2024 in Jacksonville Beach, (32250)

Plumber Notes: We turn the water off to the facility at the backflow, bleed out the residual water that was still in the pipe. Then disconnect the electrical to the existing pump and the 1/2in union at the discharge port. Cut out the 1in 1/4 copper pipe before the union at the inlet port, disconnect the union at the outlet port, remove the brass T at the outlet port. Then dismount the existing booster pump and reinstall the existing T the new booster pump at the outlet port. We mount the new boost pump on the the existing wood panel and reconnect the electrical to the new boost pump. During the repair we notice that the existing electrical wiring was incorrect. We re-pipe both inlet and outlet port with propress fittings and turn the water back on to the facility at the backflow. We turn on all fixtures in property to make sure that the store has the right pressure and reprogram the Lenze control box unit to the new booster pump. Check for leaks, no leaks. During the final inspection for the water pressure to the facility. We notice that all the Sloane valve in both bathroom need to be replace with a new one or changing out the diaphragm. Joe did approve to change out the sloane valve which will be in different ticket…. read more