Water Heater Plumbing Service in Jacksonville, FL (32205)
Date: October 28, 2024
City: Jacksonville, FL
ZIP Code: 32205
Plumber Notes: Upon arrival I found the gas meter unlocked and the test gauge still intact. I started by removing the test rig and undoing the 6”nipple with cap coming from meter. I have to run and grab a smaller nipple to complete the installation. After reconnecting the gas line to the gas meter I went to restart the pilot light in the water heater in the garage. The pilot light did not light so I am going to try and clean the igniter. After trying to clean the igniter assembly and checking the gas lines for any clogs I was still unable to get the pilot lit. After talking and sending pictures to my team lead he recommended to replace the heater as it is almost 10 years old and is located in an area that elements are a factor in the life of the heater.